<\/span><\/h2>\nTransmitted lightning is when a lightning strikes a certain location, within a radius of 2km from the location of the lightning strike, it will electromagnetically induce electrical wires, metal objects, and data transmission lines nearby leading to damaged.<\/span><\/span><\/p>\n<\/span>1. Statistics of lightning transmission<\/span><\/span><\/h3>\nAccording to statistics on the phenomenon of lightning transmission:<\/span><\/span><\/p>\n\nEvery day around the world there will be about 8 million lightning bolts.<\/span><\/span><\/li>\nThe highest structure is the point of contact with the possibility of being struck by lightning.<\/span><\/span><\/li>\nDespite the fact that some structures are more likely to attract lightning, lightning is unpredictable.<\/span><\/span><\/li>\n<\/ul>\n<\/span>2. Risk of damage to electronic devices<\/span><\/span><\/h3>\nRisk of destruction of electronic devices<\/span><\/em><\/figcaption><\/figure>\nHigh surge voltage has the potential to enter the home through direct or indirect lightning strikes. For direct lightning, the lightning goes straight through the building, causing serious damage to the factory, while for indirect lightning, the lightning strikes the adjacent ground, the power line connects directly to the house. When this happens, any electronic equipment can be destroyed.<\/span><\/span><\/p>\nThe result: Not only high replacement costs for electronic devices and circuits, but also disrupted connections to personal devices.<\/span><\/span><\/p>\n<\/span>3. Simulate the path of lightning<\/span><\/span><\/h3>\nWhen lightning strikes close to an unprotected building, it travels inside through a power line that connects directly to the switchboard. When lightning strikes a building with a lightning rod, the voltage is transmitted directly to the ground around the house. However, half of the voltage can still enter the house through the electrical circuit.<\/span><\/span><\/p>\n<\/span>What is surge protection?<\/span><\/span><\/h2>\nSurge protection is an activity of arranging lightning arresters and filters in order to limit the sudden surge overvoltages that propagate on power or signal lines by redirecting this dangerous current to another place (grounding ground). safely.<\/span><\/p>\nWhat is a surge arrester? Is a device designed to help protect electromagnetic devices, voltage surges. The purpose is to limit the increase of supply voltage to electrical equipment by drawing to ground when encountering unwanted voltage above the safe threshold.<\/span><\/span><\/p>\nSurge surge arresters and voltage surge reducers are mainly installed in the main power supply cabinets of buildings, factories, factories, floor distribution electrical panels, right in front of PLC, telecommunications, and receiver equipment. – signal generation, IT,… protection against voltage and current fluctuations, even in the event of a lightning strike.<\/span><\/span><\/p>\n<\/span>Working principle of surge arrester<\/span><\/span><\/h2>\nThe operating principle of\u00a0 <\/span>the surge arrester<\/span><\/strong> \u00a0is based on the protection circuit principle. When lightning strikes the system, the device will immediately perform the lightning protection function. Through the filter, they suppress the noise of lightning on electrical equipment to protect the overvoltage and overload of the line without short-circuiting.<\/span><\/p>\nBased on the 2-phase or 3-phase power supply to select the protection mode for the surge arrester: 2 modes, 3 modes, 4 modes, 7 modes, 10 modes.<\/span><\/p>\nWorking principle of surge arrester<\/span><\/em><\/figcaption><\/figure>\nIn the electrical equipment market, the surge protection device of the Schneider brand is considered the best with extremely effective power system protection technologies such as:<\/span><\/p>\n\nTechnology to protect modes<\/span><\/li>\nThermal fuse technology.<\/span><\/li>\nOn-board heat dissipation technology to ensure lightning surge cutting is done safely.<\/span><\/li>\nEliminate lightning surges effectively.<\/span><\/li>\nAvoid the situation that the electrical system is overloaded or over-voltage<\/span><\/li>\n<\/ul>\nSchneider surge arresters apply advanced sine wave correction technology to prevent lightning from affecting all electrical equipment operations, ensuring stable sine waves and good power supply at all locations. regime.<\/span><\/p>\n<\/span>Classification of Lightning Propagation System<\/span><\/strong><\/span><\/h2>\nSurge protection devices are divided into 3 types, specifically as follows:<\/span><\/p>\n<\/span>1. SPD Type 1 . Lightning Protection<\/span><\/strong><\/span><\/h3>\n\nType 1 surge arresters are recommended for use in specific cases such as factories, buildings, industrial plants, etc., which are protected by a lightning protection system or a direct lightning grid cage.<\/span><\/li>\nThis device protects the electrical system. Class 1 SPDs are capable of discharging reverse currents due to the backflow of lightning from the ground conductor to the conductors of the mains system.<\/span><\/li>\nClass 1 surge arresters are characterized by a 10\/350\u00b5s waveform current.<\/span><\/li>\n<\/ul>\n<\/span>2. SPD Type 2 . Lightning Protection<\/span><\/strong><\/span><\/h3>\n\nClass 2 surge arresters are the main protection system for all low voltage electrical equipment. This device is installed in each electronic to prevent overvoltage propagation in the power system and protect the loads.<\/span><\/li>\nClass 2 surge arresters are characterized by a waveform current of 8\/20\u00b5s.<\/span><\/li>\n<\/ul>\n<\/span>3. SPD Type 3 . Lightning Protection<\/span><\/strong><\/span><\/h3>\n\nClass 3 surge arresters have a low discharge capacity. For this reason, they must be installed optionally as additional equipment for Class 2 SPDs and in the vicinity of sensitive loads.<\/span><\/li>\nClass 2 surge arresters are characterized by a combination of voltage waves (1.2\/50\u00b5s) and current waves (8\/20\u00b5s).<\/span><\/li>\n<\/ul>\n<\/span>Popular Surge Protection Devices<\/span><\/strong><\/span><\/h2>\nPopular Surge Protection Devices<\/span><\/em><\/figcaption><\/figure>\nSchneider surge arrester is a line of high quality, efficient lightning protection products that is being used by many units.<\/span><\/p>\nThe Schneider surge arrester is a high quality product manufactured on modern lines meeting European standards, bringing accuracy, flexibility as well as the best user experience.<\/span><\/p>\nCurrently, on the market, customers can find and buy Schneider surge protection devices with models such as:<\/span><\/p>\n\nActi 9 . surge arrester<\/span><\/li>\nEasy 9 . surge arrester<\/span><\/li>\n<\/ul>\n<\/span>Note when installing surge protection<\/span><\/strong><\/span><\/h2>\nIn addition to understanding the principle of surge protection, the following notes will ensure an effective surge protection installation. To optimize the lightning protection system, it is necessary to determine the installation location according to the following criteria:<\/span><\/p>\nNote when installing surge protection<\/span><\/em><\/figcaption><\/figure>\n<\/span>1. Primary lightning cutting layer<\/span><\/strong><\/span><\/h3>\nThis floor will protect all mechanical equipment in the house. It is necessary to install the primary lightning arrester at the input for large projects. When directly struck by lightning, these floor equipment plays the most important role. It has the maximum lightning breaking capacity, the lightning breaking capacity is satisfactory when more than or equal to 100 kA.<\/span><\/p>\n<\/span>2. Secondary lightning cutting layer<\/span><\/strong><\/span><\/h3>\nThe secondary cut-off stage can reduce residual voltage. This floor is applied to select equipment in distribution cabinets. The secondary lightning cut stage has the function of protecting branch circuit equipment from surge surges. These surges are generated internally from the main circuit by devices in the circuit including: switchgear, pulse interference. Pulse contamination usually accounts for 70\u201380% of the damage to sensitive electrical and electronic equipment.<\/span><\/p>\n<\/span>3. Circuit of electrical equipment causing interference<\/span><\/strong><\/span><\/h3>\nCircuits of electrical equipment that cause interference are used to prevent electrical disturbances from returning. It causes damage to devices in other circuits. Circuit of electrical equipment jamming to protect inverter and industrial electrical equipment.<\/span><\/p>\n<\/span>4. Residual voltage of lightning protection device<\/span><\/strong><\/span><\/h3>\nAfter being subjected to lightning impulses and surges, this is the remaining voltage. The smaller the residual voltage, the better.<\/span><\/p>\n<\/span>