<\/span><\/h2>\nChiller central air conditioning system<\/span><\/strong> \u00a0is a cluster of machinery lines that work in combination to create a cold source to be able to cool objects, food, equipment, machinery, etc. The water is cooled through the evaporator. steam normally enters 12\u00b0C and exits 7\u00b0C. Chiller central air conditioning system is often used for high-rise buildings or commercial centers.<\/span><\/p>\nWhat is a central chiller air conditioning system?<\/span><\/em><\/figcaption><\/figure>\n<\/span>Working principle of central air conditioning system Chiller<\/span><\/span><\/h2>\nThe water is transported and recirculated in the pipeline through the chiller cooled down to 7\u00b0C. Then flows through the heat exchangers FCU\/AHU. The cold water is heat exchanged with the circulating air in the room and causes the room temperature to drop.<\/span><\/p>\nAt the same time, the temperature inside the chiller system increases to 12\u00b0C due to the heat exchange process. Next, the water will be circulated back to the chiller and cooled down to 7\u00b0C again. The process is continuously repeated.<\/span><\/p>\n<\/span>Structure of central air conditioning system Chiller<\/span><\/span><\/h2>\nThe structure of the system consists of 5 main parts:<\/span><\/p>\n\nWater chiller center cluster.<\/span><\/li>\nChilled water piping system and chilled water pump.<\/span><\/li>\nLoad system for direct use: AHU, FCU, PAU, PHE, etc.<\/span><\/li>\nIndirectly used load system: Valve system, air duct, air outlet, expansion tank, etc.<\/span><\/li>\nPumping system \u2013 circulating water through Cooling Tower (if any) for water cooling chiller system.<\/span><\/li>\n<\/ol>\n<\/span>Advantages of central air conditioning system Chiller<\/span><\/span><\/h2>\n\nLarge operating capacity from 5 to 1000 tons.<\/span><\/li>\nThe pipe system is compact, easy to install in locations in the building without taking up much space.<\/span><\/li>\nStable operation system, high durability can be used for a long time.<\/span><\/li>\nUsing chilled water, so you don’t have to worry about refrigerant leakage.<\/span><\/li>\nEasily adjust the operating capacity, humidity for the rooms to help save power consumption, save monthly costs for investors.<\/span><\/li>\nThe system is suitable for installation for many large projects.<\/span><\/li>\nThe variety in operating capacity as well as types of machines, cooling systems, heat exchangers, etc.<\/span><\/li>\n<\/ul>\n<\/span>How many types of chiller central air conditioners are there?<\/span><\/strong><\/span><\/h2>\nThere are 2 types of central chiller air conditioners:<\/span><\/p>\n<\/span>1. Central air conditioning system Chiller cooling wind<\/span><\/strong><\/span><\/h3>\nThis system includes central air conditioning, cold air distribution channels, condenser cooling device, etc., which operate according to the mechanism of air cooling and condenser cooling by wind. Accordingly, the central air conditioner produces cold wind and delivers it to the conditioned spaces through the air ducts.<\/span><\/p>\nHere, the cold wind acts as a heat exchanger, carrying out the process of receiving heat from the environment in the room, reducing\/increasing the temperature and humidity in the room. After completing the process, cold wind is recirculated to the central air conditioner through another wind channel.<\/span><\/p>\n<\/span>2. Water cooling chiller central air conditioning system<\/span><\/strong><\/span><\/h3>\nThis system includes central air conditioning, heat exchangers, condenser cooling equipment, water pump, … operating by the mechanism of water cooling and condenser cooling by wind. Accordingly, cold water produced at central air conditioners is supplied to heat exchangers located in spaces that need air conditioning.<\/span><\/p>\nHere, water acts as a heat exchanger, performing the process of receiving heat from the environment in the room, reducing\/increasing the temperature and humidity in the room. After completing this process, the water is recirculated to the central air conditioner and continues a new cycle. This water-cooled chiller central air conditioning system is suitable for the air conditioning requirements for different spaces, with different temperature and humidity regimes. Does not require high installation space. The distance between the false ceiling and the bottom is about 100-200 mm.<\/span><\/p>\n<\/span>Instructions for installing central air conditioner chiller properly<\/span><\/span><\/span><\/h2>\nIn essence when designing or installing chiller central air conditioning systems for buildings or apartments. People often use the air conditioning system in combination with the indoor unit hidden in the ceiling. It is both aesthetically pleasing and safe. The cold air used for cooling will be blown through the air outlet to cool the entire house. . The following are the steps to install a chiller central air conditioning system for your reference.<\/span><\/p>\nInstructions for installing central air conditioner chiller properly<\/span><\/em><\/figcaption><\/figure>\n