<\/span><\/h2>\nInstalling a factory ventilation system helps:<\/span><\/p>\n\nEliminate harmful gases and unnecessary gases inside the workshop to the outside environment. Normally, CO2 is the gas that needs to be eliminated most in human living spaces.<\/span><\/li>\nEnsure that the air quality in the workplace is always clean and well-ventilated.<\/span><\/li>\nRemove excess moisture and heat to the outside.<\/span><\/li>\nProduce the required amount of oxygen for people working in the workshop.<\/span><\/li>\nIn some more special cases, ventilation systems are installed to overcome unexpected problems in the production process such as leakage of hazardous substances.<\/span><\/li>\n<\/ul>\nCurrently, businesses are using two ventilation systems for factories, namely the ventilation system in the air-conditioned environment and the ventilation system to create cool ventilation.<\/span><\/p>\nWhy ventilate the factory?<\/span><\/em><\/figcaption><\/figure>\n<\/span>The formula for calculating the design of factory ventilation flow<\/span><\/span><\/span><\/h2>\nOne of the important stages in the process of calculating and designing the factory ventilation system is determining the required air flow. Thereby, the new team of engineers can make a suitable design and select equipment that brings high efficiency. Refer to the two popular ways of calculating air flow below.<\/span><\/p>\n<\/span>1. How to calculate the ventilation volume according to the volume of the workshop<\/span><\/strong><\/span><\/span><\/h3>\nBased on the volume of the factory or factory, the enterprise applies the following formula to calculate the air flow:<\/span><\/p>\nTg = X*T<\/span><\/strong><\/span><\/p>\nIn there:<\/span><\/p>\n\nX is the number of times the air in the workshop needs to be replaced (times\/hour).<\/span><\/li>\nT is the volume of the factory or factory (T = DxRxC), (m3).<\/span><\/li>\nTg is the total required ventilation volume for the factory (m3\/h).<\/span><\/li>\n<\/ul>\n<\/span>2. How to calculate the factory ventilation volume based on the number of people<\/span><\/strong><\/span><\/span><\/h3>\nHow to calculate the second factory ventilation system flow based on the number of workers working in the factory.<\/span><\/p>\nIn Vietnam, the government stipulates that each worker needs to provide 20m3 of fresh wind in an hour. Therefore, the amount of fresh air to be supplied to the factory is calculated by applying the formula:<\/span><\/p>\nTg = N*20<\/span><\/strong><\/span><\/p>\nIn there:<\/span><\/p>\n\nN is the number of employees working in the factory (N = Area\/0.7).<\/span><\/li>\nTg is the total required ventilation volume for the workshop (m3).<\/span><\/li>\n<\/ul>\n<\/span>The formula for calculating the design of the factory ventilation system<\/span><\/span><\/span><\/h2>\nAfter calculating the amount of wind to provide, the enterprise calculates the design of the fan system, ventilation pipe and the number of Cooling Pads in the factory accordingly. Here are 3 formulas and calculations for factory ventilation that you can use to find the above values.<\/span><\/p>\nHow to calculate the air flow in the factory using the standard formula<\/span><\/em><\/figcaption><\/figure>\n<\/span>1. How to calculate the number of factory ventilation fan equipment<\/span><\/strong><\/span><\/span><\/h3>\nDetermining the number of fans to use is an indispensable step in the design calculation of the factory ventilation system. When determining the exact number of factory ventilation equipment needed, businesses can measure costs quickly. The simple calculation formula is as follows:<\/span><\/p>\nM = Tg\/Q<\/span><\/strong><\/span><\/p>\nIn there:<\/span><\/p>\n\nTg is the total amount of fresh air to be supplied to the factory (m3\/h).<\/span><\/li>\nQ is the wind flow of the fan unit (m3\/h).<\/span><\/li>\nM is the number of exhaust fans required.<\/span><\/li>\n<\/ul>\n<\/span>2. Calculation formula for factory ventilation pipe design<\/span><\/strong><\/span><\/span><\/h3>\nCurrently, to calculate and design the factory ventilation pipeline system, businesses can use many different ways, but in general, the ways are reduced to the method below.<\/span><\/p>\nStep 1:<\/span><\/strong> Determine the wind speed of the first pipe section (\u03c91), then based on the wind flow (L) to calculate the cross-sectional area (f) of that pipe section according to the formula:<\/span><\/p>\nf = L\/\u03c9<\/span><\/strong><\/span><\/p>\nStep 2:<\/span><\/strong> \u00a0Continue to calculate the wind speed of other pipe sections of the factory ventilation system according to the formula:<\/span><\/p>\np*[(\u03c91)^2 \u2013 (\u03c92)^2]\/2 \u2013 p12 = 0<\/span><\/strong><\/span><\/p>\nIn there:<\/span><\/strong><\/p>\n\n\u03c91:<\/span><\/strong> \u00a0Wind speed of the first pipe section. <\/span> \n\u03c92:<\/span><\/strong> \u00a0Wind speed of the second pipe section.<\/span><\/li>\n\u2211\u0394p122.:<\/span><\/strong> \u00a0Total voltage loss calculated from branching point 1 to branching point 2.<\/span><\/li>\n<\/ul>\nThen based on the wind speed and flow of the next section to determine the cross-sectional area of \u200b\u200bthat section:\u00a0 <\/span>f2 = L2\/\u03c92.<\/span><\/strong><\/p>\nStep 3:<\/span><\/strong> \u00a0Repeat the calculation in step 2 until the speed and size of all remaining ducts in the factory ventilation system are determined. The total length of the main pipe is equal to the sum of the lengths of the pipe segments plus the length of the elbow.<\/span><\/p>\n<\/span>3. Formula to calculate the number of Cooling Pads to use<\/span><\/span><\/h3>\nCooling Pad<\/span><\/strong> \u00a0is an important part with the role of heat exchanger in the factory ventilation system. To calculate the number of\u00a0 <\/span>Cooling Pads<\/span><\/strong> \u00a0needed to design a factory ventilation system, the following steps should be followed:<\/span><\/p>\nCalculate the total area of \u200b\u200bthe Cooling Pad:<\/span><\/strong><\/p>\nS = V*X\/9000<\/span><\/strong><\/span><\/p>\nIn there:<\/span><\/p>\n\nV is the volume of the workshop (V = DxRxC), (m3).<\/span><\/strong><\/li>\nX is the number of fresh wind changes.<\/span><\/strong><\/li>\nS is the total area of \u200b\u200bthe Cooling Pad (m2).<\/span><\/strong><\/li>\n<\/ul>\n<\/span>How to calculate the number of fans by area, ventilation fan capacity for the factory<\/span><\/strong><\/span><\/h2>\nYou can refer to how to calculate the total air flow to install the appropriate factory ventilation fan<\/span><\/p>\nStep 1\u00a0<\/span><\/strong> : Calculate the volume of the space:<\/span><\/p>\n( <\/span>V<\/span><\/strong> ) =\u00a0 <\/span>Length<\/span><\/strong> \u00a0x\u00a0 <\/span>width\u00a0<\/span><\/strong>